Pass the menu and read the page

SignupFolio

2 signup outage pages to build before launch day

GOV.UK's notification banner guidance asks services on GOV.UK to check that two error pages are set up when demand is higher than usual: a "There is a problem with the service" page and a "Service unavailable" page. Write them before launch, not during the incident, and route each one to the right failure case.

  • The problem page covers a specific failed request (a timed-out POST, an expired session); the unavailable page covers the whole service being down.
  • Wording on both pages has four jobs: state the problem, avoid blame, give a next action, and give a human route — keep body copy short.
  • Error pages must not depend on the component that just failed; serve them as static pages from a different path.
  • Check third-party API limits against your expected spike before launch; when a limit trips, the user sees your page.
  • Test locally by breaking each dependency one at a time, then in staging, then with a realistic spiky load test.

Why two error pages matter on launch day

GOV.UK's banner guidance asks GOV.UK services to check these two pages are set up whenever demand runs higher than usual. The GOV.UK Design System notification banner page says exactly this: if your service is getting more demand than usual, check that you have set up those two pages and that the wording is up to date (GOV.UK Design System).

That is the whole instruction in one line. Most teams build the happy path and a generic error page. Then launch day arrives, the signup form times out, and a visitor lands on a blank white screen with a stack trace on it. That screen is your service's face at its busiest moment.

Growth leads know the shape of launch day. A press mention, a product directory, a partner email — traffic jumps, the queue backs up, and someone's browser gives up. The moment it gives up is a request that fails. What the visitor sees next is a choice you made weeks earlier, or a default you never touched.

This page walks through the two pages, what each one is for, how the wording works under the GOV.UK Design System, and how backend capacity and API limits relate to the moment a user sees the error. The final checklist ties it together.

What each page is for

"There is a problem with the service" tells a user that something has gone wrong on their side of the transaction. They tried to sign up, and it did not go through. The page names the problem and points them to what to do next.

"Service unavailable" tells the user the service itself is down or paused. Nobody can get through, not just this person. The tone is different. One is "your action failed"; the other is "we are down."

The GOV.UK Design System pages describe both as service pages you set up in advance. The notification banner page points you at them together, which means you write them at the same time, not after the incident.

Choosing which to show depends on what failed. If a single form submission errored, the problem page fits. If the whole signup backend is down, the unavailable page fits. Pick one, hard-code the decision in your error routing, and do not improvise during the incident.

There is a common temptation to write one page that covers both cases with hedging language. Resist it. The user's next action differs. On the problem page, they retry or contact you. On the unavailable page, they leave and come back. Wording that says "maybe, maybe not" makes both actions unclear.

Wording rules that apply to both

The GOV.UK Design System notification banner page asks you to check that these two pages are set up and the wording is up to date, and the four-part rules below are this article's own recommendation, not quoted from any source. Keep sentences short and lead with what happened, then what the user should do.

Write the page before launch, not during. The notification banner page's instruction to check your pages "and the wording is up to date" assumes a wording already exists. There is nothing to update if you never wrote one.

Avoid these common errors: apologising seventeen times, blaming the user's browser, promising a fix time you cannot keep, and burying the retry link under a paragraph of internal jargon. Each of those turns a small failure into a trust event.

Do not put a signup form on the error page itself. If the backend is down, the form fails again. If a single submission failed, the form pre-filled with their data may fail on retry for the same reason. The error page's job is routing, not conversion.

When each page should appear

Route the problem page when a specific request fails: a form POST times out, a payment or email-verification step returns an error, a session expires mid-signup. The user was mid-action.

Route the unavailable page when the service as a whole is not answering: the health check fails, the database is saturated, the upstream dependency is down, or you are deliberately pausing signups to drain a queue.

If you can tell the difference in your error handler, do. Many teams cannot, and they default to one page for everything. A single page for both cases is acceptable only if its wording avoids hedging across the two situations. What is not defensible is no default at all — the raw framework error page.

One practical test: kill your main application process locally and load the signup URL. What you see is your unavailable page. Then break only the form-submit handler and submit the form. What you see is your problem page. If both look identical, your routing is not doing its job.

Timing matters too.

What the wording must do

The wording on both pages has four jobs: state the problem, avoid blame, give a next action, and give a way to reach a human. Everything else is optional.

State the problem in the first sentence. Not "Oops!" but "We could not save your signup." The user should know within one line whether this is them or you.

Avoid blame. Never "you entered the wrong thing" when you do not know that. Never "your connection is unstable" unless you measured it. Keep the no-blame rule: state that the service could not do the thing, full stop.

Give a next action. Retry, wait and come back, or contact support. One clear action beats three vague ones. If you offer a retry control, make it a real link that restarts the flow cleanly, without re-submitting data from the error page.

Give a human route. An email address or a support link, with expected response time if you can commit to one. On launch day the volume may exceed what you committed to, so commit conservatively.

Keep it short enough to read in one screen. A user who hit an error is already annoyed. A wall of text makes it worse. Aim to keep body copy tight and scannable.

Do not put a ticket number or internal error code as the headline. Put it small, at the bottom, for your own debugging. The headline is for the user.

What usually causes the error

The two pages sit at the end of a chain. Knowing what breaks helps you word them and helps you decide which one to show.

Capacity. Your app server has a concurrency limit. Your database has a connection pool. Your email provider has a rate limit. When launch traffic exceeds any of these, requests queue, then time out. The user sees an error you could have predicted.

API request limits. If your signup flow calls third-party APIs, those APIs have request limits tied to your plan. Microsoft's Power Platform documentation states that requests generated by running certain apps count toward a license limit of 40,000 requests each user each 24-hour period (Microsoft Learn). That is one platform's rule for one product family. The general point stands: find your own providers' request limits before launch.

Stacked entitlements. On the same platform, limits can add. The Microsoft page gives an example: a user with both a Dynamics 365 Customer Service Enterprise base license and a Power Apps license for individual users has 40,000 + 40,000 requests available in each 24-hour window. If you assumed the lower number, you planned the wrong capacity.

Reserved capacity for one flow. The same page notes that the Power Automate plan reserved to a single flow allows capacity to be set aside for that one flow, irrespective of the flow's owner. Reserving capacity for a critical path — your signup flow — is a pattern worth asking your vendors about.

Microsoft documents that when a tenant has one or more Copilot Studio packs, Power Automate cloud flows that a Copilot Studio agent triggers can use up to 250,000 Power Platform requests for each tenant in a rolling 24-hour period. A chained automation you set up months ago can consume launch-day capacity you did not budget.

Read your own entitlement line before you assume which limit applies to your signup traffic.

None of this is GOV.UK's subject. It is here because the error pages are the visible end of these invisible limits. When the limit trips, the user sees your page.

Here is a compact view of what the Microsoft documentation states, for one product family only, as a shape of the problem:

Capacity pattern (Power Platform, on Microsoft Learn)What it states
App requests for individual users40,000 requests each user each 24-hour period
Stacked licenses example40,000 + 40,000 requests in each 24 hours
Plan reserved to a single flowCapacity set aside for one flow, whoever owns it
Copilot Studio agent-triggered flowsUp to 250,000 requests each tenant, rolling 24-hour period

What to check in your own signup flow

Walk your signup as a user, then break it on purpose.

Submit the form with the network throttled. Watch what happens when the POST times out. That is the case your problem page is for.

Stop your app server and load the URL. That is the case your unavailable page is for.

Check every third-party call in the flow: email sending, CAPTCHA, enrichment, CRM write, analytics. Each has a limit. Each can fail independently. Decide in advance which failure shows which page.

Check your session and cookie handling. A user who starts a signup, gets pulled away, and returns later may hit a stale session. That is a problem-page case, not an unavailable-page case.

Check your retry behavior. If a user retries a timed-out POST and the original eventually succeeded, they may now have a duplicate record. Your problem page should say what to do: wait, or contact you, not "just try again" if a retry creates a duplicate.

Check your queue. If signups land in a queue that you drain later, the user may have succeeded even though they saw an error. Word the page to match that reality: "we received it, we will confirm by email" is a different message from "it failed."

Check your monitoring. If you cannot see the failure, you cannot route the user to the right page. Wire your error pages to a real health signal, not a guess.

If you use client-side anonymous auth or a similar pattern, note where errors surface. Firebase's anonymous authentication guide puts the point plainly: "This is also where you can catch and handle errors" (Firebase). Catch them there, and route from there.

How to test before launch day

Test in this order: locally, in staging, and with a load test that mimics your expected spike.

Locally, break each dependency one at a time and confirm the right page appears with the right wording. Screenshot each. Keep the screenshots next to the wording spec so you can see what a real user sees.

In staging, run the full flow with production-like data volumes. Confirm that error pages do not themselves depend on the component that just failed — no error page that loads its content from the database that is down.

Load test with a realistic shape, not a flat line. Launch traffic is spiky: a burst, a plateau, a second burst when the email lands. Ask your infrastructure team what concurrency your app can hold and what your database pool size is. Those two numbers, plus your third-party request and email limits, bound your spike ceiling.

Rehearse the failure with the team. Someone says "the signup POST is timing out," and you decide in the room which page goes up. Do it once out loud before you do it on launch morning.

Write the wording and get it approved before launch. If legal or compliance must sign off, start that thread now. A wording review on launch morning is how vague, hedged copy gets shipped.

Keep a copy of both pages in version control. If the deploy pipeline that carries your pages shares a failure mode with the app, your error pages may go down with it. Static pages served from a different path are more robust.

Checklist to run the day before

Here is the pre-launch pass, in order:

  • Both pages written, approved, and reachable on a URL you control.
  • Routing tested: problem case and unavailable case show different pages.
  • Error pages do not depend on the component that fails.
  • Wording reviewed for the four jobs: state, no blame, next action, human route.
  • Retry behavior confirmed to not create duplicates.
  • Third-party call limits checked against your expected spike volume.
  • Health signal wired to the unavailable route.
  • Team rehearsed the decision out loud once.
  • Screenshots of both pages stored with the wording spec.
  • A named person owns the page swap on launch day.

The last item matters most. Someone has to be on the hook for flipping the pages. Without a name, the flip happens by committee, late, and badly.

FAQ

What if we only have time for one page? Build the unavailable page first. Then add the problem page for the partial-failure case as soon as you can.

Should the error page still carry our brand look? Keep your header and footer so the user knows they are still on your site. Keep the body minimal. A heavy, animated error page is slow to load exactly when your server is slow.

How long should we keep a page up? Until the underlying condition clears and you have confirmed it with a real test, not just a dashboard green light. Load the signup yourself before you take the page down.

Do we need different pages for mobile? One page with responsive layout is enough. Check that the retry link and support link are both thumb-reachable on a phone.

What if the error page itself is cached? If a CDN caches your error page across users, a single user's problem-page may be served to everyone. Configure cache rules so error responses are not stored, or serve them with headers that prevent shared caching.

For your own infrastructure limits, ask your vendors directly in writing before launch, because the entitlement that applies to you is specific to your plan and your account.

Sources and check date

Related posts

More posts