Choose a signup login method by agreeing on an assurance target with engineering and checking how each login option meets it.
Key takeaways
- Write down the target assurance level and its owner.
- Ask engineering to check each login option against the guideline.
- Review account recovery alongside signup and sign-in.
- Match the page's security claims to what engineering can show.
Why the login choice is a business choice
Every signup form asks the visitor to prove something. Sometimes the proof is a password. Sometimes it is a button that hands the job to a large account provider. Sometimes it is a passkey, or a one-time code sent to a phone. Each of these is a login method, and each gives the company a different level of confidence that the person typing is the real account owner.
Marketers usually weigh these options by conversion, brand fit, and how much friction the form creates. Those concerns are real. But the login method also decides how hard it is for someone else to get into an account. That affects customers, the legal and security teams, and the engineers who run the product after launch. When marketing and engineering use different words for the same decision, the meeting goes in circles. A shared vocabulary fixes most of that.
This post introduces the central idea, the assurance level, and walks through the three levels in a guideline for remote login. It then explains the engineering terms you will hear and ends with questions to bring to your engineering lead. It does not tell you which option to pick. That depends on what your product holds and who uses it.
What an assurance level is
An assurance level is a rating of how confident a system can be that the person logging in is the account owner. It is not a rating of how nice the login screen looks. It measures how hard it is for a wrong person to get in, and how sure the system is that the right person did.
The definitions come from the National Institute of Standards and Technology (NIST). Its NIST Special Publication 800-63B sets out requirements for remote user authentication at three authentication assurance levels, called AAL1, AAL2, and AAL3. The document addresses credential service providers. Your own login system may play that role, and so may a third-party sign-in service you rely on.
In general, each higher level asks for more proof, or for proof that is harder to steal or fake.
Level 1: AAL1, the single factor
AAL1 is the entry level. The guideline states that AAL1 requires only single-factor authentication using a wide range of available authentication technologies. One factor is enough to meet the level, and the guideline does not limit that factor to one kind of technology.
A factor is a piece of evidence used to prove identity. Security people usually sort factors into three groups: something you know, such as a password or PIN; something you have, such as a phone or a hardware key; something you are, such as a fingerprint or a face. A signup form that asks only for an email address and a password is a single-factor login, and that is the kind of login AAL1 describes.
Single-factor does not automatically mean unsafe. It does mean that one piece of evidence carries the whole decision. If that evidence is guessed, reused from a data breach, or typed into a fake page, the login has no backup check.
The guideline also makes a recommendation for this level: it is recommended that applications assessed at AAL1 offer multi-factor authentication options. Multi-factor means the login asks for more than one factor. The wording is a recommendation, not a requirement, and it talks about offering options. For a marketer, the practical question is whether a second factor is available at all, and whether it is shown at signup or hidden deep in settings.
Level 2: AAL2, the phishing-resistant requirement
AAL2 raises the bar in one specific way. The guideline says that Applications assessed at AAL2 must offer a phishing-resistant authentication. The key verb is "offer." The rule is that the application makes a phishing-resistant method available. It does not say every user must be forced onto it.
Phishing is the trick where someone is led to a fake sign-in page and types in a password or code, which the attacker then uses on the real site. Phishing-resistant methods are designed so that a fake page cannot easily capture the login. Whether a particular option qualifies is a question for engineering to answer against the guideline, not something a marketing page can settle by claiming it.
A one-time code sent by text or email is useful, but a person can still be tricked into typing it into a fake page. Asking for a code is not the same thing.
Here is why this matters for signup. If your form offers a password and then a code on the next screen, a reviewer may ask where the phishing-resistant option is. If the product does not offer one, it does not meet that part of the requirement, and that gap will come up in security reviews, enterprise deals, and audits. Raise the question before the design is final, not after launch.
Level 3: AAL3, a key and two factors
AAL3 is the highest level in this guideline, and it asks for the most. The guideline explains that authentication at AAL3 is based on the proof of possession of a key through the use of a public-key cryptographic protocol. In plain words, the user shows that they hold a specific key. The check uses public-key cryptography, a method in which a linked pair of keys lets one party prove something to another without sharing the secret half.
The guideline also states that to authenticate at AAL3, claimants are required to prove possession and control of two distinct authentication factors. "Claimant" is the guideline's term for the person trying to log in. Taken together, the two statements make AAL3 a heavier lift than the levels below it.
Whether a product needs AAL3 is a risk decision for the people who own that risk, not a marketing decision. If your product holds sensitive data or handles money, raise the question early. That way the signup form is not designed around a level the product cannot support.
Illustrative example: reviewing a signup flow
An illustrative signup flow has 2 screens: a password screen and a code screen. In 1 review, marketing and engineering walk through both, check whether a phishing-resistant method is available, and compare the page's claims with the actual flow. They record questions before changing the copy; counting screens alone does not establish an assurance level.
The words engineers use
Engineering teams use a set of terms that sound alike but mean different things. Here is a short glossary of the ones that come up most often in login planning.
- Authentication means proving that a person or device is who it claims to be. The person being checked is the claimant.
- Authorization means deciding what an authenticated person is allowed to do. Login answers who you are. Authorization answers what you can touch.
- Factor is one piece of evidence, usually something you know, have, or are.
- Single-factor means one factor is used. Multi-factor means more than one is used.
- Phishing-resistant means the method is designed so a fake sign-in page cannot easily collect the login.
- Session is the period after a successful login when the system remembers the user, so they do not have to sign in again on every page.
When you offer sign-in with a large provider, the vocabulary gets more specific. Google's developer documentation for OAuth 2.0 web server applications lists key concepts, including scopes, access tokens, refresh tokens, redirect URIs, incremental authorization, revocation, time-based access, and cross-account protection. Ask engineering which concepts affect your flow; use the access scopes review to prepare questions.
Mapping common signup options to the levels
Each option has its own profile. Check each one on its own terms, because the weakest path through the form often sets the real risk. Use the list below as a set of prompts, not a verdict. The point is to see what each option asks of the person and what the product promises in return.
- Email and password only. Ask where a second factor is offered and how the user finds it.
- Email and password, plus a one-time code. Ask engineering what the code proves and whether a phishing-resistant method is also available.
- Sign in with a large provider. The provider checks the person. Your assurance depends on how that provider authenticates users and on what your app asks for in return. Look at the scopes your app requests, not only at the button.
- Passkey. Confirm with engineering how your implementation fits the guideline before the word appears on the page.
Each option may be fine on its own. What matters is the combination the person actually sees on the form.
Who decides the level
A login level is a decision, not a feature. Someone has to choose the target, and someone has to check that the product meets it. In most teams, a product or security owner sets the target, engineering builds and tests the flow, and legal or compliance may need the answer for contracts and questionnaires. Marketing's job is to make sure the promise on the page matches that decision.
If nobody can say which level the signup flow targets, that is the first thing to fix. Write the target down, name the owner, and keep the record with the product documentation. A decision that lives only in a meeting is hard to defend later, and it is easy to change by accident during a redesign.
Writing about login on the page
The words on the form are where marketing and engineering meet. Phrases like "bank-level security" or "fully secure" are hard to check, and they invite a question that nobody on the team can answer. A plainer line tells the reader what happens and is easier to verify. "Sign in with a passkey" describes an action. "Sign in with your work account" names the provider the person will use. Both give a reviewer something concrete to compare with the product.
Avoid promising a level you have not confirmed. If the page says a method is phishing-resistant, that claim should trace back to how the product works, not to a label from a vendor. Have engineering walk you through the flow from the first signup screen to the first sign-in, and check that the page matches what they show. Use the signup authentication testing guide to plan that review.
Today, take a screenshot of the signup form and ask engineering to mark each login option with the level it is designed to meet. Use the questions below to record the answers.
Questions to bring to engineering
Bring these to your engineering lead before the design is final. Write down the answers.
- Which assurance level is the signup login aiming for, and who approved that target? A product or security owner should identify the target and its approval.
- Which login options appear on the signup page, and which are hidden in settings? Check the signup page and settings together to answer this.
- Is a phishing-resistant option offered on signup and on sign-in? If not, why not? Engineering should demonstrate its availability in the actual flow.
- Is a multi-factor option offered, and is it presented as an option rather than buried? Walk through the screens to check where users find it.
- For sign-in with a large provider, which scopes do we request, and can users revoke access later? Ask engineering to identify the requested scopes and access controls.
- How long does a session last after login, and how does a user end it? Engineering should demonstrate the session's duration and ending behavior.
- How does account recovery work, and could recovery be used to get around the login? Review the recovery flow alongside the normal login checks.
- Can we describe our level in one sentence for a customer's security questionnaire? Use a sentence that matches the agreed target and tested flow.
Common mistakes to avoid
- Counting buttons as assurance. Adding more sign-in options does not raise the level. Each option has to be checked on its own.
- Treating social sign-in as a fixed level. The level depends on the provider and on how your app uses the result.
- Testing away a second factor. Removing a second factor to lift conversion changes the security design. It needs review, not only an A/B test.
- Using the words interchangeably. "Secure," "strong," "multi-factor," and "phishing-resistant" are different claims. When a claim might be checked, use the guideline's terms.
- Forgetting recovery. A login is only as strong as the way someone gets back in after losing access.
- Forgetting the second screen. A signup flow can offer one method on the first screen and a different one later. Review every screen a person sees, not only the first.
- Launching without an owner. If nobody owns the login decision after launch, changes made for other goals can slip in unnoticed. Name the person who signs off on login changes.
Where this leaves you
Choosing a login method is a shared decision. Marketing owns the promise and the form's design. Engineering owns the checks behind the promise. Use the three levels to describe what each option gives you, use the terms above to ask precise questions, and keep a record of the answers. A line on the form is a claim about the product, and it should match what engineering can show.