To set entry fields that fit NIST's guidance, allow passphrases of at least 64 characters and give one-time code fields at least 10 entry attempts. The same SP 800-63B text also asks for fonts that clearly tell apart look-alike characters, such as the capital letter O and the number zero.
Everyday takeaways
- Set the passphrase field to accept at least 64 characters, and test a long entry before launch.
- Give one-time code fields at least 10 entry attempts, so a single mistyped code does not stop a signup.
- Pick a font in which a capital O and a zero look clearly different in every code field.
- Treat accessibility as a build requirement. Section508.gov states the goal plainly: make information and communication technology (ICT) accessible to people with disabilities.
- Read the Firebase password guidance as one layer of protection. It says enforcing password complexity requirements can improve account security, so pair complexity with length.
Start with the accessibility duty
Section 508 supplies the accessibility purpose behind the checks in this post, so the guidance starts there. NIST's SP 800-63B points to Section 508 of the Rehabilitation Act of 1973. The law was enacted to eliminate barriers in information technology and to require federal agencies to make electronic and information technology accessible to people with disabilities.
Two parts of that sentence matter for a growth team. The first is purpose. The law targets barriers in information technology. A passphrase box that a person cannot read, or a code box that rejects a reasonable correction, is a barrier even if the page loads and the form submits. The second is audience. The sentence names federal agencies as the parties it requires to make technology accessible. That distinction is worth keeping clear in internal debates, because it changes who is accountable, not whether the goal is worth pursuing.
Use that purpose as a test when you review a signup page. Can the visitor see what they typed? Can they correct a mistake without starting over? Can someone using assistive technology reach the field and understand what it asks for? None of these questions requires a number. The figures in NIST's guidance set a floor for passphrase length and entry attempts. The purpose of the law tells you whether a field that clears the floor still works for the people it is meant to serve.
Who the accessibility expectation reaches
NIST's text links the guidelines to the wider law. Identity service providers are expected to comply with Section 508 provisions. The table names the parties and scope the quoted text covers, and what each one is expected to do.
| Named party or scope | What is expected | Source |
|---|---|---|
| Identity service providers | Compliance with Section 508 provisions | NIST SP 800-63B |
| Federal agencies and their service providers | Design for the experiences of people with disabilities, beyond compliance with Section 508 | NIST SP 800-63B |
| Identity system life cycles | Accessibility prioritized throughout the life cycle | NIST SP 800-63B |
Read the rows as a chain. Identity service providers face the most direct expectation, which is compliance with the Section 508 provisions. Federal agencies and their service providers face a wider one. The quoted text says they are generally expected to design with people with disabilities in mind, and the phrase "beyond compliance" tells you the bar is not met by a checklist alone.
The third row is about time. Accessibility is meant to be prioritized throughout identity system life cycles, from the first design of a sign-in or account flow through changes made long after launch. For a marketer, that means a field review is not a single pre-launch task. A new campaign that adds a verification step, or a redesign that changes the passphrase box, starts the same review again.
Whether this applies to your form depends on what the form does. If your signup creates accounts and collects passphrases or one-time codes, it is the kind of identity system this text describes, and the expectations above are the ones to plan around. If it only collects an email address for a newsletter, the accessibility goal in the law is still worth meeting, but the identity rules in this post answer a different question.
Fonts that keep look-alike characters apart
Most visitors never think about the font inside a code box, but NIST's SP 800-63B asks for one that does a specific job: fonts that clearly distinguish between characters that are easily confused. The text gives its own example, the capital letter "O" and the number zero "0".
Stated that way, the requirement is about the font, not about the field's length or its rules. A font passes when the two characters look different to the person viewing them. The review step is simple. Open the actual signup page on a phone and on a laptop, type a sample code that contains a capital O and a zero, and confirm you can tell them apart at a glance. Test at the size a visitor will see, because a font that separates the characters at a large size can blur them when the page is small.
The same reasoning applies to codes a visitor copies from an email or text message. You control the field where the visitor types the code and the wording near it, but you do not control every screen that displays the code. Keep the instructions plain, and do not wrap the code in a decorative style that changes the shapes of characters. A clear font in your own field is the part of this requirement that you can fully deliver.
Attempt limits for one-time code fields
NIST's text sets a floor for how many times a visitor may try to enter an authenticator's output. The SP 800-63B guidance says to allow at least 10 entry attempts for authenticators that require the user to enter the output. The floor is a minimum, and the table sets the two field types side by side on the same three measures.
| Measure | Passphrase field | One-time code field |
|---|---|---|
| Figure from the quoted text | At least 64 characters in length | At least 10 entry attempts |
| What the figure governs | Length of the passphrase | Attempts to enter the authenticator output |
| Source | NIST SP 800-63B | NIST SP 800-63B |
The comparison shows the logic clearly. A passphrase field has a length floor, and a one-time code field has an attempt floor. Each figure is a minimum you must meet, so the team's preference for a tidy, tight form does not override it.
The attempt floor matters most when a visitor is on a slow connection, reading a message on one device and typing on another, or working from a phone keyboard. A typo on the first try is common enough that a limit of one or two attempts would cut people off before they reach the correct code. The quoted text sets 10 as the minimum you may use, so a lower limit goes against the guidance. Build the field so that a failed attempt tells the visitor what happened and lets them try again, rather than sending them back to the start of the signup.
Passphrase length of at least 64 characters
NIST's SP 800-63B text says to allow at least 64 characters in length to support the use of passphrases. The verb matters. It asks the field to accept at least that many, so a form that caps input below that length falls short of the text, even if the cap looks reasonable to the design team.
A passphrase is a longer phrase than a typical password, and this figure reflects that choice. A signup form that trims input at the length of an older password box would not meet this sentence, even if the rest of the form is accessible and well designed. Check the field's maximum length in the code and confirm that a long test entry is accepted in full before you launch.
The table lists each source used in this section and the fact it supports.
| Source | Publisher site | Fact used in this post |
|---|---|---|
| NIST SP 800-63B | nist.gov | Allow at least 64 characters in length for passphrases |
| Section508.gov | section508.gov | Make ICT accessible to people with disabilities |
| Firebase password guide | google.com | Enforcing password complexity requirements can improve account security |
Each row answers a different question. The NIST figure governs length, Section508.gov states the accessibility goal, and the Firebase guidance points to complexity as a separate lever. Complexity and length are different controls. A passphrase can be long and simple, and a password can be short and complex. Keep the two apart when you write your field rules, so that a complexity requirement is never presented as a replacement for the length floor.
What the ICT accessibility goal means for signup
The Section508.gov laws and policies page states the goal in one sentence: make information and communication technology (ICT) accessible to people with disabilities. The sentence is short, but it covers every screen a visitor sees on the way to finishing a signup. It is not limited to the final confirmation page or to one button.
For a growth team, "ICT" is the practical word. A signup form is ICT in the plainest sense. It includes the page layout, the labels, the passphrase box, the code entry field, the error messages, and the button that moves the visitor forward. If any one of those parts blocks a person with a disability, the form falls short of the goal, even when the conversion rate looks healthy on the dashboard.
Turning the goal into work means asking concrete questions about each field. Does the field have a visible label that stays on screen while the visitor types? Does an error message say what went wrong in words that assistive technology can announce? Can the visitor move through the fields with a keyboard alone? These are design and build questions. They do not change the passphrase or code rules covered earlier in this post. They sit alongside those rules and decide whether the rules actually help people use the form. For error wording, see signup form validation messages.
Treat the goal as a requirement for the current sprint, not a note for a later cleanup. Put accessibility checks in the same ticket as the field setting. When a passphrase field passes the length floor but its label is unreadable, the ticket is not finished.
Why password complexity rules fall short
The Firebase guidance on password-based accounts makes a useful point here. It says you can improve account security by enforcing password complexity requirements. That sentence is a claim about what complexity rules can do, and it stops there. Complexity is one control, and it does not replace the length floor that NIST sets for passphrases.
Complexity rules usually ask for a mix of character types, such as an uppercase letter, a digit, and a symbol. For a signup form, the trouble is that these rules can push visitors toward short strings that are hard to recall. A long passphrase is often easier to remember than a short string that satisfies a checklist of symbols. NIST's SP 800-63B text frames the passphrase requirement around length: allow at least 64 characters to support the use of passphrases.
Read complexity as one layer, not the foundation. The Firebase sentence names complexity as a way to improve security. Length is a separate control, and the NIST figure sets its floor. A form can enforce both, but the length floor is the minimum the quoted NIST text states, so it should be the first setting you check. For a wider list of password checks, see signup password rules.
When you review the form, watch for a complexity rule that rejects a valid long passphrase. If a visitor types a long phrase with spaces and the form says it lacks a symbol, the rule has become a barrier. That failure counts against both the accessibility purpose and the length guidance, because the field no longer accepts the entry the floor was written to allow.
Which one should you pick?
The choice is not between a strong password and a weak one. For a signup form that offers passphrases and one-time codes, the real question is which rules to make mandatory and which to layer on top. The table compares three options against the figures and purposes in the quoted text.
| Option | What it sets | How it fits the quoted text |
|---|---|---|
| Complexity rules only | A required mix of character types | Rests on the Firebase point that complexity can improve security, and leaves out the NIST length floor |
| Length floor with optional complexity | Accepts at least 64 characters; complexity is advisory | Meets NIST's figure of at least 64 characters for passphrases |
| Length floor plus required complexity | Accepts at least 64 characters; complexity is mandatory | Meets NIST's figure only if the complexity rule never blocks or caps a long entry |
For most passphrase fields, the second option is the safest default. It gives the one figure the NIST text states, and it keeps the form open to long entries. The third option can work, but only if testing shows the complexity rule never rejects a valid phrase. The first option is the least complete match for the quoted text, because it leaves out the length floor entirely.
Whichever option you choose, write the decision down with the field's test results. A future redesign may add a complexity rule for a good reason, and the record will show whether it still accepts 64 characters. Make that check part of the change request, so the decision is revisited whenever the field changes.
Checking field accessibility before launch
Before launch, run the passphrase and code fields against the goal from Section508.gov: make ICT accessible to people with disabilities. The checks below cover the specific settings from this post and the accessibility basics that surround them. Run them on a phone and a laptop, and record the results in the ticket. For a broader review, see Section 508 signup pages: 6 checks before launch.
- Enter a long test passphrase and confirm the field accepts it in full. The NIST text says to allow at least 64 characters.
- Enter a wrong one-time code several times and confirm the field allows at least 10 entry attempts before anything else happens.
- Type a sample code that contains a capital O and a zero, and confirm the characters look clearly different at the size a visitor will see.
- Move through the whole form with a keyboard only. Confirm that focus is visible on each field and that the order follows the page.
- Use a screen reader to check that each field's label is announced and that error messages are read aloud.
- Trigger an error on purpose and confirm the message says what to fix, in plain words.
Keep the list with the release notes. When a field changes, repeat the checks for that field only. The accessibility goal applies to the whole form, so a passing length test alone does not close the ticket.
Worked example: code attempts
Worked example: this example is illustrative. Suppose a one-time code field allows 10 entry attempts, the minimum in the quoted text. A visitor mistypes the code 4 times, which leaves 6 attempts. The field accepts the next try, and the signup finishes without a restart.
Passphrase and one-time code fields side by side
The two fields share a purpose but have different minimums and different risks. The table sets out the figure from the quoted text for each field, along with the check that proves the field meets it.
| Field | Minimum from the quoted text | Check before launch |
|---|---|---|
| Passphrase | Allow at least 64 characters in length | A long test entry is accepted in full, with no hidden cap |
| One-time code | Allow at least 10 entry attempts | A failed attempt returns the visitor to the code step with a clear message |
| Code font | Fonts that clearly distinguish easily confused characters, such as capital O and zero | The O and the zero look different on both phone and laptop |
Both figures are floors. Going above them is allowed, but the team should not treat the floors as targets to trim. A form that accepts 64 characters and permits 10 attempts meets the minimum, and the same form with a tighter limit does not. The NIST SP 800-63B text states both figures, so cite it in the ticket when a reviewer asks why the limit is set where it is.
The fields also share an audience. A visitor may reach both in a single session, possibly on one device and copying from a message on another. Test the two fields together, using the same test account and the same device, so a problem in one does not hide a problem in the other. A passing test on each field alone does not show that the whole flow works for a visitor who moves between them.
Your next step today: enter a test passphrase of at least 64 characters into your signup form and confirm the field accepts it in full.
Related guides: 3 fields to set on an Intercom checklist for new users · Signup field error messages: 3 rules for limits · A/B test split and stop rules: 5 tools compared.
Reader questions
Does the accessibility goal apply to my signup form? Whether it applies depends on what your form does. The Section508.gov page states the goal of making ICT accessible to people with disabilities. The NIST text says identity service providers are expected to comply with Section 508 provisions, so confirm the scope with whoever owns compliance on your team.
Is 64 characters a maximum for passphrases? No. The NIST text says to allow at least 64 characters, so 64 is a floor for what the field must accept. Set the field so that a long entry of that length or more is accepted in full.
Can a one-time code field allow fewer than 10 attempts? No. The NIST text says to allow at least 10 entry attempts for authenticators that require the user to enter the output, and a lower limit goes against that sentence.
Does a complexity rule satisfy the NIST length guidance? No. The Firebase guidance says complexity requirements can improve account security. The NIST text sets a length floor for passphrases. Enforce both where they fit, and make sure complexity never blocks an entry of 64 characters.
Why does the font in a code field matter? It decides whether a visitor can tell similar characters apart. The NIST text asks for fonts that clearly distinguish easily confused characters, using the capital letter O and the number zero as its example. A visitor reading a code should be able to tell those two apart without effort.
Do these rules cover every accessibility issue? No. The NIST figures set specific minimums for two fields, and the Section508.gov goal is much broader. Labels, keyboard use, error messages, and screen reader behavior still need their own checks.
Does the Section 508 law apply directly to private companies? The law, as quoted in NIST's text, makes federal agencies responsible for accessible technology. Identity service providers are still expected to comply with its provisions, so treat the goal as the working standard for your form.