GrowthBook metric delay sets when conversion counting starts relative to experiment entry: zero starts immediately, positive starts later, and negative includes earlier conversions.
Key takeaways
- Check how long users take to reach your activation event.
- Separate the delay from the time available before analysis stops.
- Justify any pre-join conversions without treating them as effects of the variant.
- Record your choice before the test starts.
This post covers the three kinds of value you are likely to use: zero, a positive number of hours, and a negative number of hours. For each one, we look at what it counts, when it fits an activation test, and where it can mislead you. The rules described here come from GrowthBook's own metrics and fact tables documentation. That page is the source for the quotes below.
What a metric delay changes
Every user in an experiment enters at a particular moment. GrowthBook counts conversions relative to that moment. The metric delay moves the start of the counting window, so the delay you pick decides which conversions fall inside it.
The reason this matters is that users do not all arrive at the same point in their journey. Some people join an experiment on their first visit. Others join after they have used the product for weeks. The documentation makes this point with a hypothetical user: "Here's a second example for a hypothetical User 2, who joins the experiment late." A late joiner has a different history from an early one, so the same conversion can mean something different for each of them.
Think of it in plain terms. Suppose your activation event is "created first project." A user who joins the test and creates a project a few minutes later gives you a fast response. A user who joins on day nine and creates a project the next morning gives you a slower one. Both are real activations. The delay setting controls how soon counting starts after joining; the analysis window also limits how late an activation can count.
Two questions guide the choice. First, how long after joining does a real activation usually happen in your product? Second, do you want to count anything that happened before the user joined? The three kinds of value answer these questions in different ways, and the rest of this post walks through each one.
Value one: zero, the default
The default delay is zero. The documentation describes the related setting this way: "Conversions within the first X hours of being put into an experiment are ignored (default = 0)." With X set to zero, no hours are skipped at the start, so conversions after the user joins can count within the analysis window. That is the simplest setting, and most teams should begin here unless they have a specific reason to change it.
Zero fits an activation event that happens in the same session. If a signup form, a setup step, or a first click is the action you care about, and it usually follows the first visit within minutes, then waiting adds nothing. Counting from the moment of exposure keeps the test close to what the user just experienced. It also keeps the result easy to explain to your team, because each conversion can be traced back to the visit that put the user into the test.
The risk is that fast actions can look like wins. A user who was already close to activating may complete the step soon after seeing the variant, and the test will credit the variant even if the change had little to do with it. Zero does not correct for that. It counts everything inside the window and leaves the interpretation to you. This is why a zero delay should be paired with a look at your baseline, not used on its own as proof.
A practical check helps here. Before you launch, pull a sample of users from the last few weeks and measure how long it takes them to complete the activation event. If most of them finish within a single session, zero is a sound choice. If a long tail finishes days later, those users may not finish before analysis stops, so check the analysis window rather than increasing the delay. Write down the number you found, because you will need it when you explain the choice later.
Value two: a positive delay
A positive delay moves the start of counting later. Conversions that happen within the first X hours after a user joins are ignored, and only later conversions count. A delay of 24 hours, for example, drops everything that happens in the first day after joining.
The documentation gives a retention example that shows when this fits: "In that case, if your underlying table reports whether a user is retained on any given day, you could set a metric delay to 24 hours." For activation, use that logic only when you deliberately want to exclude early actions. If the action you care about is something a user does the next day, such as coming back to finish a setup step or confirming an account, decide whether same-day completions should still count. A positive delay excludes them; it does not give slower users more time.
This choice has a clear cost. Early conversions are removed from the result entirely, so if they were your main signal, the test will look weaker than it really is. You also wait longer. A test that needed a week of data may need a week plus the delay before the conversions you care about appear in the results. Plan for that in your timeline rather than discovering it on the day you wanted to decide.
A positive delay also interacts with late joiners. A user who joins late has less time left before your analysis stops, so they have less chance to convert inside your window. Check how much of your sample still has time after the delay to reach the event. If a large share of late joiners cannot possibly finish the window, the result may mostly reflect early joiners, and you should say so in your report.
The positive setting is most useful when you have a clear reason to think that early conversions are noise. For instance, if your product sends a welcome email that prompts an immediate click, many of those early clicks may reflect the email rather than the product experience you are testing. Removing that first window can give you a cleaner read on the behavior that comes after it. The question to answer before you choose is simple: would an early conversion tell you something about the variant, or only about a prompt that happened to fire? Review your first-session messages alongside that decision.
Value three: a negative delay
A negative delay does the opposite. It pulls the start of the window earlier, so conversions that happen before a user joined the experiment can count. The documentation gives the exact meaning: "For example, a value of -2 would mean conversions up to 2 hours before will be included." Under that setting, a conversion that happened two hours before the user was put into the test is counted.
The documentation also gives a reason to use one: "If you set the metric delay to something negative, say -0.5 (30 minutes), you can reduce the amount of data you need to see patterns." In other words, a negative value can let you read a pattern from less data, because it widens the set of conversions that qualify. For a test with modest traffic, that can matter a great deal, since waiting for more users may mean a longer test.
The cost is conceptual, and it is easy to overlook. A conversion that happened before the user saw the variant cannot have been caused by the variant. Counting it does not make the arithmetic wrong, but it can make the story wrong. If many users activate just before they are assigned to a test, a negative window may credit the test with behavior that was already underway. The result can look like a lift that was there before the experiment started.
Suppose your experiment triggers on a page that people usually visit right before they activate. Check whether conversions before that trigger belong in the metric at all. If the experiment triggers on a page that people visit after they have already decided to sign up, including those earlier actions can blur the behavior you intended to measure.
Keep the window short. The documentation's example of -0.5 (30 minutes) is a useful reference point for how short a window can be, and a short window is much easier to defend in a review than a long one. If you find yourself needing many hours before the join, that is a sign the metric or the trigger point needs a second look before you rely on the result.
Comparing the three values
The table sets the three options side by side. Read it as a set of questions rather than a ranking. The right value depends on when your activation event happens and how much data you can gather. None of the three is better in general.
| Delay value | Which conversions count | Fits an activation test when | Main risk |
|---|---|---|---|
| Zero (default) | Conversions after joining, within the analysis window | Early activations belong in the metric | Quick actions may be credited to the variant without much context |
| Positive, such as 24 hours | Conversions after the delay, within the analysis window | You deliberately want to exclude early activations | Early conversions are dropped, and results take longer |
| Negative, such as -0.5 (30 minutes) | Includes conversions in the chosen pre-join window | You have a clear reason to include earlier actions | Pre-join conversions may have little to do with the variant |
The table is a summary, so keep the reasons next to it. Each choice trades one kind of cost for another, and the test plan should name the trade you are making.
Illustrative example: check the start time
Suppose an illustrative test uses a positive delay of 1 hour. A conversion 10 minutes after joining is excluded; a conversion 90 minutes after joining is eligible if the analysis window still includes it. With zero delay, both are eligible within that window. Increasing the delay does not rescue a late conversion cut off by the end of analysis.
Choosing a value for your activation test
Start with the timing of the event. For your activation metric, write down how long a typical user takes from joining the test to completing the event. Use past data from your own product rather than a guess.
If most activations happen within the session, start at zero. If many of them happen the next day or later, allow enough analysis time; choose a positive delay only if early activations should be excluded. If your traffic is light and the event sits just before the join point, a short negative window may help you see a pattern sooner, but only if you can defend the logic to your team in plain words.
The documentation uses a time-on-site example to show why a single delay value cannot fit every user. It starts with an average visit: "Imagine the average person stays on your site for 60 seconds and your experiment can trigger at any time." Then it shows that the same value can land very differently depending on where a user is in their visit. "A value of 20 seconds might be horrible if it happened to someone after only 5 seconds on your site since they are staying a lot less time than average." And in the other direction: "But, that same 20 seconds might be great if it happened to someone after 55 seconds since their visit is a lot longer than usual."
The same lesson carries over to activation. A delay chosen for the typical user can be too short for someone who is slow to act and too long for someone who acts almost at once. You cannot make one number fit everybody. What you can do is pick the value that fits the typical user, check the spread around it, and be honest about who falls outside the window.
When you write the decision up, keep three things together: the event you counted, the delay you chose, and the typical time from joining to that event. Those three facts let a reader check your reasoning without rerunning the test. If you cannot state all three, the result is not ready to share, even if the numbers look clear. They also make the setup easier to reuse for the next activation test, since you will already know how long your users take to act and which window matched that pattern.
Decide the value before the test starts and write it into the plan. Changing it after you see results makes it easy to pick the version that flatters the variant, and that undermines the whole point of running a test. If you later decide that a different value would have been better, record that as a lesson for the next test rather than rewriting the current one. For related planning, review test split and stop rules.
Before you launch
Put the delay value in the test plan with a short reason. A reviewer should be able to read one line and understand why you chose zero, a positive delay, or a negative delay. That line also helps the next person on your team who inherits the test and wonders why the metric counts what it counts.
Check the sample against the window. Confirm that enough users have time after joining to reach the activation event inside the window you chose. If the window is long and your traffic is recent, many users may still be in progress when you look, and the result will understate the metric. Note the gap in the report rather than hiding it.
If you want to see how sensitive the result is to the delay, you can compare a few values as a sensitivity check. Label that comparison clearly, and do not choose the winner from it. The purpose of the check is to show whether the conclusion holds across reasonable choices, not to find the one value that produces the answer you want.
Finally, keep the metric definition stable. Changing the delay, the event, and the traffic source all at once makes it hard to say what changed. Change one thing at a time, and write each change down. A small amount of discipline here saves a lot of argument later, when someone asks why the activation number moved.
Today, pull a sample of recent activation times and write your proposed delay beside the event definition, with a short reason for including or excluding early actions.
Related guides: Event naming mistakes: 3 fixes for activation reports · GrowthBook revenue caps: 6 steps for trial tests · Activation trend chart: 2 smoothing windows.
Questions about metric delay
Does a slower activation require a positive delay?
No, a slower activation requires enough time before analysis stops. Check whether early completions belong in the metric before choosing to exclude them.
Can I change the delay after seeing results?
Use alternative values as a clearly labelled sensitivity check, keeping the original choice for the test decision. Record any better choice as a lesson for the next test.