Microsoft Entra signup field requests use four terms: built-in user attributes, custom user attributes, the extensions app, and the programmable name.
Key takeaways
- Check whether an existing attribute fits your field.
- Ask engineering whether the field uses an extension attribute.
- Confirm the programmable name and every system that will read it.
- Include the purpose and visible label in your brief.
Most growth marketers first meet Microsoft Entra External ID through a request that stalls. You ask engineering to "add a field to signup," and the reply comes back with questions you cannot answer on the spot. Is this a built-in attribute or a custom one? Where is the data stored? What name will the code use? Those are normal questions for any user data, and they rely on a small set of terms that Microsoft defines in its documentation.
This post explains each term in plain language, puts them side by side in a table, walks through one realistic signup field, and includes a list of details to put in your brief. The main source is Microsoft's user profile attributes page, with the W3C's guidance on headings and labels for the form side.
Fixing this does not require learning to code. It requires a short shared vocabulary, a habit of naming the kind of field you want, and one extra question before the build starts. The rest of this post gives you that vocabulary.
Why the vocabulary matters
Engineering and marketing look at the same user data from different sides. Marketing thinks in questions: who signed up, what did they tell us, and what should we send them next. Engineering thinks in names: which field, which store, and which identifier the code reads. When one side's words do not match the other's, a simple request grows into several rounds of messages, and each round tends to add a new question.
Take a common case. A growth lead asks for "the company size field" in a meeting. The engineer hears a new field, builds a new attribute with a name that suits the code, and the marketer later discovers the welcome email flow reads a different field name. Nobody made a mistake on purpose. The two sides were describing one idea with two vocabularies.
This matters more for growth teams than it might seem. Fields collected at signup often feed segments, campaigns, and reports after the account is created. Agreeing on the name before several systems start reading it can help avoid later changes.
The four terms work as a translation layer. If you know them, you can say what the field is, which kind of field it is, and what it should be called in code, all in one message. You do not have to know how the code works. You only have to name the right kind of thing and let engineering confirm it.
Keep the vocabulary light in the first conversation. You do not need to present the four terms as a lecture. Use them as labels for the questions you already have. If an engineer says "built-in," ask which existing attribute fits. If they say "extension," you know to ask about the app.
Built-in and custom attributes
The first split to learn is between built-in and custom attributes. Microsoft's user profile attributes page puts it in one sentence: "You can choose from built-in user attributes or create custom user attributes."
Built-in attributes are the fields that already exist. The page gives examples: "Built-in user attributes, such as city, country/region, email address, and so on, are available in Microsoft Entra External ID." If an existing attribute fits, ask engineering to confirm its use. You ask for the existing field by name, and the remaining work is about where it appears on the form and how your team uses it afterward.
Custom attributes are the fields you create. The same page says, "For any additional information you want to collect, you can create custom user attributes." Ask engineering whether an existing attribute covers the information you want. A referral partner code, a preferred onboarding track, or a team size needs that check before you classify it.
For a growth marketer, the practical test is straightforward. Before you make a request, review the built-in attributes Microsoft's page describes, including city, country/region, and email address. If an existing attribute fits, request it by its name. Otherwise, ask engineering whether you need a custom attribute. Writing "new field" without that distinction is the quickest way to start an open-ended thread, because engineering then has to ask which kind you mean before doing anything else.
There is a second reason to review existing attributes first. A field that already exists is usually easier to discuss, because the name is settled. A custom field adds a decision each time someone touches it, from the form to the reports. That is not a reason to avoid custom fields. It is a reason to request them on purpose.
Keep a running list of planned fields with a built-in or custom tag next to each one. Your list then becomes the agenda for the engineering meeting, and no one has to guess what you meant.
The extensions app and programmable names
Two more terms are useful when discussing storage and code. Both are easy to skip, and skipping them is where many follow-up questions start.
The first is the extensions app. The Microsoft page says, "All extension attributes for your external tenant are stored in an app named b2c-extensions-app." Ask engineering whether your requested field will be stored as an extension attribute. That confirmation tells you whether this app belongs in your brief. It also gives engineering an exact name to look up. The same page points to a separate article on finding the application ID for the b2c-extensions-app registered in your external tenant, so the app ID is something your engineers can look up rather than guess.
The second is the programmable name. Microsoft defines it this way: "Programmable name is the name of the user attribute as used in the user resource of the Microsoft Graph API." The same page explains when it matters: "You use this name when you want to use this user attribute programmatically, such as in native authentication."
In practice, the programmable name is the name the code reads. Your team may describe a field in everyday words, such as "company size" or "preferred language," but those words may differ from its programmable name. A nickname in a brief is not enough. The brief should carry the exact programmable name that engineering will use, confirmed against the attribute as it exists in your tenant.
A rough mental model helps here. Think of the extensions app as the place where extension attributes are kept, and the programmable name as the identifier code uses for an attribute. The model is a simplification, so confirm the details with engineering, but it keeps the two questions apart in your head.
The four terms side by side
The four terms below come from the Microsoft user profile attributes page. The table adds the question each one should prompt in your brief.
| Term | Question to ask before you request it |
|---|---|
| Built-in user attribute | Does an existing attribute fit? |
| Custom user attribute | Does this need a new field? |
| Extensions app (b2c-extensions-app) | Is this an extension attribute, and which application ID applies? |
| Programmable name | What exact name will the code read? |
Read down the questions and you have an agenda for your next meeting.
Use the table as a checklist, not as a ranking. None of the four terms is better than the others. Each answers a different question, and a single signup field usually needs an answer for more than one of them. A custom field, for example, needs both naming and storage decisions confirmed.
Walking through one field
Take company size, a field many teams ask for at signup. Suppose your team wants to know how large a prospect's company is at signup, so sales can prioritize follow-up and the welcome sequence can differ by segment. Here is how the four terms apply, in order.
Start with the built-in question. The examples on the Microsoft page are city, country/region, and email address, and company size is not among them. Ask engineering whether an existing attribute fits before deciding you need a custom one.
Next, the storage question. If engineering confirms the field uses an extension attribute, name the extensions app in your request and ask engineering to confirm the application ID for your tenant using the Microsoft page. Marketing does not need to find the ID itself. It only needs to make sure the answer is written down before the build starts.
Then the naming question. Pick the programmable name with engineering at the start, and write it down exactly. Changing it later means checking every place it was used.
Last, the reading question. Write down everything that will read the value. Include any sign-up or sign-in flow that uses it programmatically. Reports and sales exports should be on the list too.
Put all four answers in the same message, along with the purpose and the label the visitor will see.
Take preferred language as a second case. It sounds familiar, but familiar is not the test. Ask engineering whether an existing attribute fits, then confirm storage and naming. The reading question matters here too, because a language value is often used to choose the copy a visitor sees.
If engineering tells you the field is hard to add, do not assume the request is wrong. Ask which step is the hard one. Is it the built-in question, the storage question, the naming question, or the reading question? A clear answer to that narrows the conversation to one decision.
Illustrative example: checking the readers
Suppose a company size field has 2 readers: the sales export and the welcome flow. Your brief names only the welcome flow. Comparing it with the reader list reveals 1 missing reader. Add the sales export before sharing the brief, so engineering can check both uses against the agreed programmable name.
Briefing engineering without guessing
A good brief is short. For each field, put these items in one message:
- Purpose. Say what you will do with the answer in one sentence. "We route enterprise prospects to sales" is more useful than "we need company size."
- Built-in or custom. Give your best guess and ask engineering to confirm whether an existing attribute fits.
- Storage. Ask whether the field uses an extension attribute; if so, confirm the extensions app's application ID.
- Programmable name. Give the exact name, not the label you use in meetings.
- Readers. List every system, flow, or report that will read the value, including any authentication flow.
- Visible label. Say what a visitor will read next to the field, and why.
Here is wording to adapt from the company size walkthrough, inserting the agreed programmable name before sharing:
> Field: company size at signup. Purpose: route enterprise prospects to sales. Built-in or custom: please confirm whether an existing attribute fits. Storage: if stored as an extension attribute, please confirm the extensions app and its application ID for our tenant. Programmable name: use the exact name already agreed with engineering. Readers: the sales export and the welcome flow. Visible label: the words a visitor reads next to the field, which we will draft together.
If engineering pushes back, ask which item is the concern rather than whether the whole request is possible. A narrow question about one item usually gets a faster answer than a broad question about everything.
Ask for the answers in writing. A short list is easier to check than a conversation, and it gives both sides something to point to when the scope changes. If engineering offers a delivery date, ask what it depends on. Treat any date as an estimate from your team.
For a related review of the systems using signup values, see onboarding email monitoring.
Labels are part of the form too
The visible label is the last item in the brief, and it is easy to file under design rather than data. It is still part of the field. A visitor reads the label, and a screen reader announces it. The W3C's guidance on headings and labels is useful here, with one nuance. The page says, "This success criterion does not require headings or labels; labels for inputs are covered separately by 3.3.2 Labels or Instructions." In other words, the rule about labels on form inputs sits under a different criterion from the headings rule.
The page also refers to Success Criterion 1.3.1 for cases where headings or labels are not correctly marked up or identified. Those cross-references are the place to look when a label question comes up, and they are more useful than a guess.
Label wording is a marketing choice as well. Short, plain words usually work better than clever ones, and the label should say what the answer is for, not only what the field is called internally. Check that the wording matches the purpose you wrote in the brief, so the visitor and the data team are talking about the same thing.
For a growth marketer, the practical step is to ask engineering to confirm that each new field has a visible label marked up as a label, and to check the form against the W3C guidance before launch. Asking that question does not require accessibility expertise. It only requires that someone on the project is responsible for the answer, and that the answer is written into the same brief as the field name.
Use the related guide to visible labels and accessible names when reviewing that wording.
Start with four answers
Today, take one planned signup field and record four answers: built-in or custom, the extensions app if engineering confirms extension storage, the programmable name, and the readers. Put those answers in writing with the purpose and the label, and your conversation with engineering starts from a plan instead of a guess.
Related guides: Child data checks: 5 rules before a signup form · Consent request on signup form: 5 checks before go-live · Embedded signup form checklist: 6 checks for release.
Questions before the build
Does company size need a custom attribute?
Ask engineering whether an existing attribute fits before requesting a custom one. Its absence from the examples alone does not settle the choice.
What should I do if the programmable name is undecided?
Resolve the name with engineering before sharing the final brief. Keep the visible label separate from the name code will use.